Your cyan toner may have an issue, but your magenta toner cartridge is toast. Look at the solid colored lines at the bottom of the config page. This tells you your immediate issue is the magenta toner cartridge. This will effect the orange. Do not use alcohol on the etb since the etb has rubber rollers and over time it will harden them. Best solution for etb is Bestine available at art supply stores. The quality test you are sending must be from the computer and the reason for the pcl xl error is the driver is pcl6. Load the pcl5 or postscript driver and the error will be gone.
↧